NIGHT CONNECTION-FIXED

NIGHT CONNECTION-FLEXIBLE

PROGRAMMING
To provide Night Connection Stations:
START
CM30
Assign a Night Connection Station to each
incoming trunk.
Assign the destination to which a call is
forwarded when the Night Connection Sta-
tion is busy/no answer.
CM41
Specify the timing for a call forwarding
when the Connection Station is no answer.
This timing is also applied to Call
NOTE:
Forwarding-Don't Answer, Auto-
matic Change of Night Service
and Group Diversion.
END
DESCRIPTION
NIGHT CONNECTION-FLEXIBLE
Y=03
(1)
000-255: Trunk No.
(2)
04: Direct-In Termination
Y=05
(1)
000-255: Trunk No.
(2)
X-XXXXXXXX: Night Connection Sta-
Y=14 When Night Connection Station
is busy
(1)
000-255: Trunk No.
(2)
01 : To TAS
04 : To Attendant Console
06 : Automatic Camp-On
15 : Keep the call ringing until the sta-
tion becomes idle
Y=16 When Night Connection Station
is no answer
(1)
000-255: Trunk No.
(2)
01 : To Attendant Console
03 : To TAS
15 : Keep the call ringing until the sta-
tion answers
Y=0
(1)
01
(2)
01-30: 4 sec.-120 sec.
If no data is set, the default setting is 32-36
sec.
– 358 –
NIGHT CONNECTION-FIXED
DATA
tion No.
(4 sec. increments)
A2356-10