A
CM81
Assign the Toll Restriction Patterns with
eight kinds of Trunk Restriction Classes
assigned by CM12 Y=01.
Toll Restriction Pattern 00-15 are preas-
signed as shown below.
If a new Restriction Pattern is required,
change the data of the Restriction Pattern
01-13 (00, 14 and 15 are fixed).
TRUNK
RESTRICTION
CLASS
1
RCA
2
RCB
3
RCC
4
RCD
5
RCE
6
RCF
7
RCG
8
RCH
0: Restricted
3: Allowed
CM85
Specify the maximum number of digits to
be dialed during an outgoing call.
The maximum number of digits, including
the area codes, should be assigned to
each area code.
B
DESCRIPTION
01
02
03
04
05
TOLL RESTRICTION PATTERN NUMBER ON EACH TRUNK RESTRICTION CLASS
01
02
03
04
05
3
0
3
3
3
0
3
3
3
0
3
0
3
0
0
0
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Y=01-13
•
Toll Restriction Pattern No. 01-13
(1)
1-8: Trunk Restriction Class
(2)
0: Restricted
3: Allowed
Y
06
07
08
09
06
07
08
09
3
0
0
0
3
0
0
0
0
3
0
0
0
0
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Y=0-4 Area Code Development Pattern
•
No. 0-4 assigned by CM35 Y=76
(1)
X-X...X
(Area Code dialed, Max. 8 digits)
(2)
01-24 : 1-24 digits
25-79 : 25-79 digits
– 528 –
TOLL RESTRICTION-3/6-DIGIT
DATA
10
11
12
13
14
10
11
12
13
14
3
3
3
3
0
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
00
15
00
3
0
3
0
3
0
3
0
3
0
3
0
3
0
3
0
A2523-10