(2) When the desired station is busy or no answer, and when you leave a message for the
station without going on-hook (using Single Digit Feature Access Code), do the following
programming in addition to the programming of item (1).
START
CM08
Specify the dialing of Single Digit Feature
Access Code while calling station hears
RBT or performs Voice Call.
Specify the dialing of Single Digit Feature
Access Code while calling station hears
busy tone.
Assign the called side for the Voice Mes-
CM15
sage Waiting-Individual.
Assign the access code for the Voice Mes-
CM20
sage Waiting-Individual.
Assign the feature key for the "Voice Mes-
CM90
sage Waiting Service-Individual Set when
the called station is no answer or busy" to
term
the D
, if required.
END
DESCRIPTION
(1)
156
(2)
0: Available
(1)
208
(2)
0: Available
Y=100
(1)
00-15: Service Restriction Class A as-
(2)
1 : Allow
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A146: Message Waiting/Message Re-
minder Search
A147: Message Waiting/Message Re-
minder Retrieve
Y=00
(1)
My Line No. +
(2)
F1085
– 584 –
VOICE MESSAGE SYSTEM
DATA
signed by CM12 Y=02
,
+ Key No.
A2580-10