GUEST ROOM TO GUEST ROOM CALLING RESTRICTION

PROGRAMMING
START
CM63
Restrict intra-office connection between
tenants.
NOTE:
This feature is only available be-
tween two stations which be-
longs to different tenants each
other.
CM10
When the external key is provided, assign
the DK card to required LEN.
The DK card number must be as-
NOTE:
signed to the first LEN (Level 0)
and the third LEN (Level 2).
Assign the external key used for canceling
CM61
the restriction to DK card or MP built-in
DK.
END
HARDWARE REQUIRED
To provide the external key for controlling this feature:
DK card or MP card (built-in DK)
External key (customer provided)
GUEST ROOM TO GUEST ROOM CALLING RESTRICTION
DESCRIPTION
Y=1
(1)
XX ZZ
XX: 00-63: Tenant No. of calling station
ZZ: 00-63: Tenant No. of called station
(2)
0: Connection is restricted
(1)
000-763: LEN
(2)
E900-E963: DK card No.
For PIM0/1: E900-E915
For PIM2/3: E916-E931
For PIM4/5: E932-E947
For PIM6/7: E948-E963
NOTE:
Y=06
(1)
XX Z
XX : 00-63: DK card No. assigned by
Z
: 0-3: Circuit No.
633: MP built-in External Key Interface
(2)
0: Restriction is canceled by turning on
the external key
– 664 –
DATA
Circuit No. 3 of E963 is used
for built-in External Key Inter-
face of MP card by setting
CM61.