NEC NEAX 2000 Programming Manual page 539

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

A
Assign the External Announcement Ma-
CM44
chine start function to the DK card.
CM90
Assign the Timed Reminder feature ac-
cess key to a D
CM08
Specify the timing for Timed Reminder
start.
CM41
Specify the duration of a Timed Reminder
call.
Specify the duration of Message Reply
Timer for Timed Reminder.
Specify the number of Timed Reminder
CM42
call attempts before abandonment.
Specify the maximum number of Timed
Reminder calls that can be set at the same
time.
END
DESCRIPTION
term
, if required.
(1)
XX Y
XX : 00-31: DK Card No. E800-E831
Y : 0-3: Circuit No.
313: MP built-in External Equipment In-
terface
(2)
0100: External Announcement Ma-
chine for Timed Reminder Call-
ing
Y=00
(1)
My Line No. +
(2)
F0024
(1)
228: Timed Reminder start timing
(2)
0 : At preset time
1 : Before 5 minutes of preset time
Y=0
(1)
23
(2)
01-08: 4 sec.-32 sec.
If no data is set, the default setting is 28-32
sec.
Y=0
(1)
52
(2)
01-99: 4 sec.-396 sec.
If no data is set, the default setting is 60-64
sec.
(1)
03
(2)
01-15: Number of attempted Timed Re-
If no data is set, the default setting is 05.
(1)
04
(2)
01-32: Max. number of stations
If no data is set, the default setting is 16.
– 519 –
TIMED REMINDER
DATA
assigned by CM10
,
+ Key No.
(4 sec. increments)
(4 sec. increments)
minder call
A2512-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neax 7400 ics m100mx

Table of Contents