B
Provide the distinctive ringing patterns to a
CM35
term
D
in behind PBX.
CM30
Specify the terminating system for incom-
ing C.O. calls.
Provide the Trunk Line Appearance-D
Assign the ringing detect timer for incom-
CM41
ing trunk calls.
Assign the Main PBX (Centrex) ringing
distinction timer.
Assign the immediate ringing guard timer
from the Main PBX (Centrex).
NOTE 1, NOTE 2
C
DESCRIPTION
on next page
NOTE 1
on next page
Y=87
•
(1)
00-63: Trunk Route No.
(2)
0 : To provide
1 : Not provided
Y=02 in Day Mode
•
Y=03 in Night Mode
•
Y=40 in Mode A
•
Y=41 in Mode B
•
(1)
000-255: Trunk No.
(2)
02: Trunk Line Appearance
03: Trunk Line Appearance + TAS
term
.
Y=18
•
(1)
000-255: Trunk No.
(2)
0 : To provide
1 : Not provided
Y=2
•
(1)
00
(2)
06-10: 192 ms.-320 ms.
If no data is set, the default setting is 256-
288 ms.
Y=2
•
(1)
40
(2)
01-15: 128 ms.-1920 ms.
If no data is set, the default setting is 1280-
1408 ms.
Y=2
•
(1)
41
(2)
00-99: 0 ms.-12672 ms.
If no data is set, the default setting is 384-
512 ms.
– 239 –
DISTINCTIVE RINGING
DATA
(32 ms. increments)
(128 ms. increments)
(128 ms. increments)