NEC NEAX 2000 Programming Manual page 43

Integrated voice server, integrated multimedia exchange
Hide thumbs Also See for NEAX 2000:
Table of Contents

Advertisement

B
CM41
When Multiple Connections is provided
(CM08>124: 0), specify the duration of
message replay for the Announcement
Service.
CM49
Assign the function for each Digital An-
nouncement Trunk card.
CM35
To provide a C.O./Tie Line party with this
service, assign the Announcement Ser-
vice Group 0-4 to the required trunk
routes.
END
A maximum of five different announcements can be accessed. There is a limit of 10
NOTE 1:
Digital Announcement Trunk Circuit for each of the five different announcements.
When recording an announcement, each Digital Announcement Trunk Circuit must be
recorded individually.
Each time a station is connected to a Digital Announcement Trunk Circuit, the message
NOTE 2:
will be repeated three times. The station will then be disconnected.
For the single connection of a Digital Announcement Trunk Circuit, the duration of an
NOTE 3:
announcement is limited to 120 seconds.
For the multi-connection of a Digital Announcement Trunk Circuit, the duration of re-
NOTE 4:
play for an announcement is programmable from 4 to 396 seconds.
DESCRIPTION
Y=0
(1)
53
(2)
01-99: 4 sec.-396 sec.
(4 sec. increments)
If no data is set, the default setting is
60-64 sec.
Y=00
(1)
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
(2)
04X Z
X: 0-4: Group No.
Z: 0-9: Message No.
Y=69 Announcement Service Group 0
Y=70 Announcement Service Group 1
Y=71 Announcement Service Group 2
Y=72 Announcement Service Group 3
Y=73 Announcement Service Group 4
(1)
00-63: Trunk Route No.
(2)
1 : Allow
– 23 –
ANNOUNCEMENT SERVICE
DATA
Card No. (EB002-EB127) as-
signed by CM10
A2018-10