No.
Name
(Hex.)
o2-07
Keypad RUN
Direction @
(0527)
Power-up
o2-09
Region Code
(050D)
o2-23
External 24V
Powerloss
(11F8)
Detection
o2-24
LED Light
Function Selection Sets the function to show the LED status rings and keypad LED
(11FE)
o2-26
Alarm display at
ext. 24V power
(1563)
o2-27
bCE Detection
Selection
(1565)

o3: Copy Function

No.
Name
(Hex.)
o3-01
Copy Keypad
Function Selection Sets the function that saves and copies drive parameters to a
(0515)
o3-02
Copy Allowed
Selection
(0516)
YASKAWA ELECTRIC SIEP C710617 05F YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the direction of motor rotation when the drive is energized and
the keypad is the Run command source.
0 : Forward
1 : Reverse
-
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to give a warning when the backup external 24 V
power supply turns off when the main circuit power supply is in
operation.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
lamps.
0 : Enable Status Ring & Keypad LED
1 : LED Status Ring Disable
2 : Keypad LED Light Disable
V/f
CL-V/f
OLV
CLV
AOLV
When you connect a backup external 24 V power supply, this
parameter sets the function to trigger an alarm when the main circuit
power supply voltage decreases.
Note:
The drive will not run when it is operating from one 24-V
external power supply.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation if the Bluetooth device is disconnected when
you operate the drive in Bluetooth Mode.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : No Alarm Display
Description
V/f
CL-V/f
OLV
CLV
AOLV
different drive with the keypad.
0 : Copy Select
1 : Backup (drive → keypad)
2 : Restore (keypad → drive)
3 : Verify (check for mismatch)
4 : Erase (backup data of keypad)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the copy function when o3-01 = 1 [Copy Keypad Function
Selection = Backup (drive → keypad)].
0 : Disabled
1 : Enabled
10.13 o: Keypad-Related Settings
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Default
Ref.
(Range)
0
1020
(0, 1)
-
-
0
1020
(0, 1)
0
1021
(0 - 2)
0
1021
(0, 1)
3
1021
(0 - 4)
Default
Ref.
(Range)
0
1021
(0 - 4)
0
1022
(0, 1)