Control Signal Timing; Case A: Vcc = 3.0 To 5.5 V, Av; Cc = 3.0 To 5.5 V, Av Ss = Av Ss; 10%, Av V = Av - Hitachi SH7032 Hardware Manual

Superh risc engine
Table of Contents

Advertisement

(2) Control Signal Timing

Table 20.5 Control Signal Timing
Case A: V
= 3.0 to 5.5 V, AV
CC
V
= AV
SS
SS
Case B: V
= 5.0 V ±10%, AV
CC
V
= AV
SS
SS
Note: * Regular-specification products; for wide-temperature-range products, Ta = –40 to +85°C
Item
RES setup time
RES pulse width
NMI reset setup time
NMI reset hold time
NMI setup time
NMI hold time
IRQ0–IRQ7 setup time (edge
detection)
IRQ0–IRQ7 setup time (level
detection)
IRQ0–IRQ7 hold time
IRQOUT output delay time
Bus request setup time
Bus acknowledge delay time 1
Bus acknowledge delay time 2
Bus 3-state delay time
474
= 3.0 to 5.5 V, AV
CC
= 0 V, Ta = –20 to +75°C * )
= 5.0 V ±10%, AV
CC
= 0 V, Ta = –20 to +75°C * )
Symbol
Min
t
320
RESS
t
20
RESW
t
320
NMIRS
t
320
NMIRH
t
160
NMIS
t
80
NMIH
t
160
IRQES
t
160
IRQLS
t
80
IRQEH
t
IRQOD
t
80
BRQS
t
BACD1
t
BACD2
t
BZD
= V
±10%, AV
CC
CC
= V
±10%, AV
CC
CC
Case A
12.5 MHz
Max
Min
200
20
200
200
100
50
100
100
50
80
50
80
80
80
= 3.0 V to AV
ref
= 4.5 V to AV
ref
Case B
20 MHz
Max
Unit Figure
ns
20.4
t
cyc
ns
ns
ns
20.5
ns
ns
ns
ns
50
ns
20.6
ns
20.7
50
ns
50
ns
50
ns
,
CC
,
CC

Hide quick links:

Advertisement

Table of Contents
loading