Pulse source only (PG2) commands

In the LPT commands, the pulse-only module (4220-PGU) is referred to as VPU1, VPU2, and so on.
The pulse-measure module (4225-PMU) is referred to as PMU1, PMU2, and so on. The 4210-CVU is
referred to as CVU1, CVU2, and so on.
Note that the 4225-PMU and 4220-PGU support the PG2 commands.
Command
arb_array
(on page 13-
131)
arb_file
(on page 13-132) Loads a waveform from an existing full-arb waveform file.
devclr
(on page 13-67)
devint
(on page 13-13)
getstatus
(on page 13-
70)
pg2_init
(on page 13-
137)
pulse_burst_count
page 13-138)
pulse_current_limit
page 13-139)
pulse_dc_output
page 13-140)
pulse_delay
(on page 13-
141)
pulse_fall
(on page 13-
142)
pulse_halt
(on page 13-
143)
pulse_init
(on page 13-
144)
pulse_load
(on page 13-
145)
pulse_output
(on page
13-146)
pulse_output_mode
page 13-147)
pulse_period
(on page
13-148)
13-6
Description
PGU, PMU. Configures the pulse card to output a pulse train using fixed voltage
values.
PMU with 4225-RPM. Sends switching commands to the 4225-RPM.
(on
PGU, PMU. Defines the parameters for a Segment Arb waveform pulse-measure
sequence.
(on
PGU, PMU. Creates a voltage segment waveform.
(on
PMU. Sets the number of iterations for load-line effect compensation (LLEC) for the
PMU.
Description
Used to define a full-arb waveform and name the file.
Sets all sources to a zero state.
Resets all active instruments in the system to their default states.
Returns the operating state of a specified instrument.
Resets the pulse card to the specified pulse mode (standard, full arb, or Segment
Arb) and its default conditions.
(on
For the burst mode, this command sets the number of pulses to output during a
burst sequence.
(on
Sets the current limit of the pulse card.
(on
Selects the DC output mode and sets the voltage level.
Sets the delay time from the trigger to when the pulse output starts.
Sets the fall transition time for the pulse output.
Stops all pulse output from the pulse card.
Resets the pulse card to the default settings for the pulse mode that is presently
selected.
Sets the output impedance for the load (DUT).
Sets the pulse output of a pulse card channel on or off.
(on
Sets the pulse output mode of a pulse card channel.
Sets the period for pulse output.
Model 4200A-SCS Parameter Analyzer Reference Manual