Parameter
Hide thumbs Also See for 4200A-SCS:
Table of Contents

Advertisement

Model 4200A-SCS Parameter Analyzer Reference Manual
PO
This command sets the output state (on or off) and mode (normal or complement) independently for each
channel.
Usage
PO A, B, C
A
B
C
Corresponding LPT library functions
pulse_output
pulse_output_mode
Example
PO 1, 1, 1
This command string turns on channel 1 of pulse card 1 and selects complement pulse output mode.
Also see
None
PS
This command resets both channels of the selected pulse card to the default settings.
Usage
PS A
A
Corresponding LPT library functions
pulse_init
Example
PS 3
This command string resets pulse card 2.
Also see
None
4200A-901-01 Rev. C / February 2017
Pulse card channel: 1 to 8; the largest value is the number of channels in the
system
Output state:
Off: 0 (default)
On: 1
Output mode:
Normal: 0 (default)
Complement: 1
(on page 13-146)
(on page 13-147)
Pulse card channel: 1 to 8; the largest value is the number of channels in the
system
(on page 13-144)