Keithley 4200A-SCS Reference Manual page 1058

Parameter
Hide thumbs Also See for 4200A-SCS:
Table of Contents

Advertisement

Model 4200A-SCS Parameter Analyzer Reference Manual
Code
-807
-808
-809
-810
-811
-812
-820
-821
-822
-823
-824
-825
-826
-827
-828
-829
-830
-831
-832
-833
-834
-835
-836
-837
-838
-839
-840
-841
-842
-843
-844
-845
-846
-847
-848
4200A-901-01 Rev. C / February 2017
Status or error titles
Function not supported by 4200-VPU.
Solid state relay control values ignored for 4200-VPU.
Time Per Point must be between %g and %g.
Attempts to control VPU trigger output are ignored by the 4200-VPU.
Measure range not valid for %s.
WARNING: Sequence %d, segment %d. Cannot measure with PGUs/VPUs.
PMU segment start value %gV at index %d does not match previous segment stop value of
%gV.
PMU segment stop time (%g) greater than segment duration (%g)
PMU sequence error for entry %d. Start value %gV does not match previous stop value of
%gV.
Start and stop window was specified for PMU segment %d, but no measurement type was
set.
Measurement type was specified for PMU segment %d, but start and stop window is
invalid.
%s set to post to column %s. Cannot fetch data that was registered as real-time.
Cannot execute PMU test. No channels defined.
Invalid pulse timing parameters in PMU Pulse IV test.
Maximum number of segments per PMU channel exceeded (%d).
The sum of base and amplitude voltages (%gV) exceeds maximum (%gV) for present
range.
Pulse waveform configuration exceeded output limits. Increase pulse period or reduce
amplitude or total time of pulsing.
Maximum number of samples per channel (%d) exceeded for PMU%d-CH%d.
Pulse slew rate is too low. Increase pulse amplitude or reduce pulse rise and fall time.
Invalid trigger source for PIV test.
Invalid pulse timing parameters.
Using the specified sample rate of %g samples/s, the time (%g) for sequence %d is too
short for a measurement.
WARNING: Sequence %d, segment %d is attempting to measure while solid state relay is
open. Disabling measurement.
No RPM connected to channel %d of PMU in slot %d.
Timing parameters specify a pulse that is too short for a measurement using %g samples/s.
Timing parameters contain measurement segments that are too short to measure using %g
samples/s.
SSR cannot be opened when using RPM ranges. Please change SSR array to enable relay
or select PMU measure range.
WARNING: SSR is open on segment immediately preceding sequence %d. Measurement
will be invalid for 25 µs while relay settles.
This test has exceeded the system power limit by %g watts.
Step size of %g is not evenly divisible by 10 ns.
Invalid combination of start %g1, stop %g2 and step %g3.
No pulse sweeper was configured - Test will not run.
Maximum Source Voltage Reached: Requested voltage across DUT resistance exceeds
maximum voltage available.
Output was not configured - Test will not run.
Sweep step count mismatch for the sweeping channels. All sweeping channels must have
same # of steps.
Section 13: LPT library function reference