Model 4200A-SCS Parameter Analyzer Reference Manual

ki82ulib user library

The user modules in the ki82ulib user library control the Model 82 C-V System. They perform
simultaneous C-V, C-t, and Q/t measurements and cable compensation. The next table lists the user
modules. It also provides the name of tests and actions in Clarius that are based on these user
modules.
ki82ulib user modules
User module
Abortmodule82
29)
CableCompensate82
page D-30)
CTsweep82
DisplayCableCompCaps82
(on page D-36)
LoadCableCorrectionCon
stants82
QTsweep82
SaveCableCompCaps82
page D-41)
SIMCVsweep82
44)

LS336ulib user library

The LS366ulib provides user modules that control the Lake Shore Cryotronics 336 Temperature
Controller.
LS336ulib user modules
User module
heaterOff
setDelay_Dialog
setSweepParams
setTemp
4200A-901-01 Rev. C / February 2017
Test and action
names
(on page D-
n/a
(on
cable-compensate
cablecomp
(on page D-33)
ctsweep
display-cap-file
n/a
(on page D-38)
qtsweep
(on
save-cap-file
savecablecompfile
(on page D-
system82-cvsweep
cvsweep
Description
Turns off heater 1 and heater 2 and disables setpoint ramping on both outputs.
Either displays a window that contains the message you specified and an OK
button, or performs the delay set by WaitTime.
Generates the list of temperatures used by setTemp when the setTemp
parameter FlagMode is set to 1. When active, it calculates the temperature
profile to be measured from the start temperature, stop temperature, and step
points input. It outputs the temperature list to the file.
Controls key aspects of the temperature controller, including setpoint, heater
parameters, and ramp rates, to allow variable temperature electrical
measurements. This routine is designed to function inside a subsite cycle test
with the heaterOff and setSweepParam routines.
Description
Puts the three System 82 instruments into a known
state when a test is aborted. This function is used by
other library modules in the atexit() function.
Performs cable compensation using known
capacitance source values.
Performs C-t measurements.
Places capacitance source values in a spreadsheet.
Read the cable compensation parameters and sends
them to the 590. This module is for internal use by the
SIMCVsweep82 and CTsweep82 modules. It is not
normally used as a stand-alone module.
Performs quasistatic measurement sweep.
Saves entered capacitance source values in a file.
Performs simultaneous C-V sweep.
Section 6: Clarius
6-313