Model 4200A-SCS Parameter Analyzer Reference Manual
Command
kibdefdelete
13-23)
kibdefint
(on page 13-24) Defines a device-dependent command sent to an instrument connected to the GPIB
kibrcv
(on page 13-25)
kibsnd
(on page 13-26)
kibspl
(on page 13-27)
kibsplw
(on page 13-28)
kspcfg
(on page 13-28)
kspdefclr
29)
kspdefdelete
13-30)
kspdefint
31)
ksprcv
(on page 13-32)
kspsnd
(on page 13-32)
PostDataDouble
page 13-33)
PostDataInt
34)
PostDataString
13-35)
rdelay
(on page 13-35)
rtfary
(on page 13-36)
savgX
(on page 13-36)
scnmeas
38)
searchX
(on page 13-38) Used to determine the voltage or current required to get a current or voltage.
setmode
sintgX
(on page 13-44)
smeasX
(on page 13-45) Allows a number of measurements to be made by a specified instrument during a
trigcomp
trigXg, trigXl
13-47)
tstdsl
(on page 13-50)
tstsel
(on page 13-50)
4200A-901-01 Rev. C / February 2017
Description
(on page
Deletes all command definitions previously made with the kibdefclr (Keithley
GPIB define device clear) and kibdefint (Keithley GPIB define device initialize)
commands.
interface.
Reads a device-dependent string from an instrument connected to the GPIB
interface.
Sends a device-dependent command to an instrument connected to the GPIB
interface.
Serial polls an instrument connected to the GPIB interface.
Synchronously serial polls an instrument connected to the GPIB interface.
Configures and allocates a serial port for RS-232 communications.
(on page 13-
Defines a device-dependent character string sent to an instrument connected to a
serial port.
(on page
Deletes all command definitions previously made with the kspdefclr (Keithley
Serial Define Device Clear) and kspdefint (Keithley Serial Define Device
Initialize) commands.
(on page 13-
Defines a device-dependent character string sent to an instrument connected to a
serial port.
Reads data from an instrument connected to a serial port.
Sends a device-dependent command to an instrument attached to a RS-232 serial
port.
(on
Posts double-precision floating point data from memory into the Clarius Analyze
sheet.
(on page 13-
Posts an integer-type data point from memory to the Clarius Analyze sheet in the
user test module and plots it on the graph.
(on page
Transfers a string from memory into the Clarius Analyze sheet in the user test
module and plots it on the graph.
Sets a user-programmable delay.
Returns the force array determined by the instrument action.
Makes an averaging measurement for every point in a sweep.
(on page 13-
Makes a single measurement on multiple instruments at the same time.
(on page 13-42) Sets instrument-specific operating mode parameters.
Makes an integrated measurement for every point in a sweep.
sweepX command. The results of the measurements are stored in the defined
array.
(on page 13-47) Causes a trigger when an instrument goes in or out of compliance.
(on page
Monitors for a predetermined level of voltage, current, or time.
Deselects a test station.
Enables or disables a test station.
Section 13: LPT library function reference
13-3