Chapter 43: Configuring IEEE 802.1ag OAM Connectivity-Fault Management
continuity-check {
interval 1s;
}
policer {
continuity-check cfm-policer;
other cfm-policer1;
# all cfm-policer2;
}
mep 1 {
interface ge-3/3/0.0;
direction up;
auto-discovery;
}
}
}
}
In the case of global CFM policing, the same policer is shared across multiple CFM
sessions. In per-session CFM policing, a separate policer must be created to rate-limit
packets specific to that session.
NOTE:
Service-level policer configuration for any two CFM sessions on the same interface
at different levels must satisfy the following constraints if the direction of the sessions
is the same:
If one session is configured with
a
or
policer all
policer other
If one session is configured with
a
or
policer all
policer other
A commit error will occur if such a configuration is committed.
NOTE: Policers with PBB and MIPs are not supported.
policer all
, then the other session cannot have
configuration.
policer other
, then the other session cannot have
configuration.
Configuring Rate Limiting of Ethernet OAM Messages