Figure 43: T1 Interfaces On A Channelized Oc12 Pic - Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual

Network interfaces configuration
Table of Contents

Advertisement

Figure 43: T1 Interfaces on a Channelized OC12 PIC

Example: Configuring T1 Interfaces
Configure the following T1 interfaces:
VT-Mapped
Configuration
M13 or C-bit
Parity-Mapped
Configuration
For a full configuration example, see the JUNOS Feature Guide.
Configuring NxDS0 Interfaces
To configure NxDS0 interfaces on a Channelized OC12 IQE PIC, perform the following
tasks:
1.
t1-0/0/0:1:1
t1-0/0/0:1:2
t1-0/0/0:1:3
t1-0/0/0:1:4
t1-0/0/0:1:5
[edit interfaces coc12-0/0/0]
partition 1 oc-slice 1 interface-type coc1;
[edit interfaces coc1-0/0/0:1]
partition 1-5 interface-type t1;
[edit interfaces coc12-0/0/0]
partition 1 oc-slice 1 interface-type coc1;
[edit interfaces coc1-0/0/0:1]
no-partition interface-type ct3;
[edit interfaces ct3-0/0/0:1]
partition 1-5 interface-type t1;
Partition the channelized OC12 IQE interface into channelized OC1 interfaces
by including the
partition
[edit interfaces coc12-fpc/pic/port]
type:
[edit interfaces coc12-fpc/pic/port]
Configuring Channelized OC12/STM4 IQ and IQE Interfaces (SONET Mode)
Chapter 19: Configuring Channelized OC12/STM4 Interfaces
,
oc-slice
, and
interface-type
hierarchy level, specifying the
statements at the
interface
coc1
439