Configuring Aggregated Ethernet Minimum Links; Configuring Hierarchical Scheduler On Aggregated Ethernet Interfaces Without Link Protection - Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual

Network interfaces configuration
Table of Contents

Advertisement

Configuring Aggregated Ethernet Minimum Links

On aggregated Ethernet interfaces, you can configure the minimum number of links
that must be up for the bundle as a whole to be labeled
must be up for the bundle to be labeled
To configure the minimum number of links:
1.
2.
On M120, M320, MX Series, T Series, and TX Matrix routers with Ethernet interfaces,
the valid range for
(16) is specified, all configured links of a bundle must be up for the bundle to be
labeled
On all other routers, the range of valid values for
8. When the maximum value (8) is specified, all configured links of a bundle must
be up for the bundle to be labeled
If the number of links configured in an aggregated Ethernet interface is less than the
minimum link value configured under the
configuration commit fails and an error message is displayed.
Configuring Hierarchical Scheduler on Aggregated Ethernet Interfaces Without
Link Protection
On aggregated Ethernet interfaces configured on the IQ2 PIC, you can configure the
hierarchical scheduler in non–link-protect mode. The M120, MX Series, and T Series
routers with aggregated Ethernet IQ2 PICs in non–link-protect mode support the
following scheduler functions:
—Links are 100 Mbps.
100m
10g
—Links are 10 Gbps.
—Links are 1 Gbps.
1g
OC192
—Links are OC192 or STM64c.
Specify that you want to configure the aggregated Ethernet options.
user@host# edit interfaces interface-name aggregated-ether-options
Configure the minimum number of links.
[edit interfaces interface-name aggregated-ether-options]
user@host# set minimum-links number
minimum-links number
.
up
Per unit scheduler
Hierarchical scheduler
Shaping at the physical interface
Chapter 35: Configuring Aggregated Ethernet Interfaces
up
. By default, only one link
.
up
is 1 through 16. When the maximum value
minimum-links number
up
.
aggregated-ether-options
Configuring Aggregated Ethernet Minimum Links
is 1 through
statement, the
657

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos 10.1

Table of Contents