Frame-Error - Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual

Network interfaces configuration
Table of Contents

Advertisement

JUNOS 10.1 Network Interfaces Configuration Guide

frame-error

frame-error count;
Syntax
Hierarchy Level
[edit protocols oam ethernet link-fault-management action-profile event link-event-rate],
[edit protocols oam link-fault-management interface interface-name event-thresholds]
Statement introduced in JUNOS Release 8.4.
Release Information
Threshold for sending frame error events or taking the action specified in the action
Description
profile.
A frame error is any frame error on the underlying physical layer. The threshold is
reached when the number of frame errors reaches the configured value within the
window. The default window is 1 second and is not configurable.
Options
count
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
1136
frame-error
—Threshold count for frame error events.
Range: 1 through 100
Configuring Threshold Values for Local Fault Events on an Interface on page 777
Configuring Threshold Values for Fault Events in an Action Profile on page 780