frame-period

frame-period count;
Syntax
Hierarchy Level
[edit protocols oam ethernet link-fault-management action-profile event link-event-rate],
[edit protocols oam link-fault-management interface interface-name event-thresholds]
Statement introduced in JUNOS Release 8.4.
Release Information
Threshold for sending frame period error events or taking the action specified in the
Description
action profile.
A frame error is any frame error on the underlying physical layer. The frame period
threshold is reached when the number of frame errors reaches the configured value
within the period window. The default period window is the number of minimum-size
frames that can be transmitted on the underlying physical layer in 1 second. The
window is not configurable.
Options
count
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
—Threshold count for frame period error events.
Range: 1 through 100
Configuring Threshold Values for Local Fault Events on an Interface on page 777
Configuring Threshold Values for Fault Events in an Action Profile on page 780