Access switching mode is supported on the 6-port, 8-port, and 16-port Gigabit Ethernet
uPIMs.
The multiport Gigabit Ethernet uPIMs are supported on the J2320, J2350, J4350, and
J6350 Services Routers.
The 6-port and 8-port multiport Gigabit Ethernet uPIM occupies a single slot and can
be installed in any slot. Because the 16-port Gigabit Ethernet uPIM is two slots high,
you cannot install a 16-port uPIM in the top slots (slots 1 and 4). Ports are numbered
0 through 5 on the 6-port Gigabit Ethernet uPIM, 0 through 7 on the 8-port Gigabit
Ethernet uPIM, and 0 through 15 on the 16-port Gigabit Ethernet uPIM.

Example: Configuring J Series Services Router Switching Interfaces

Configure a single physical interface for the uPIM and set the port parameters for
port 0 and port 1:

MX Series Router Interface Identifiers

The MX Series routers use the convention
fpc
located. Specifically, it is the number of the slot in which the card is installed. If two
Switch Control Boards (SCBs) are installed in an MX960 router, the FPC range is from
0 through 11. If three SCBs are installed, the range is from 0 through 5 and from 7
through 11. On the MX480 router, the range is from 0 through 6. On the MX240
router, the range is from 0 through 2 with one SCB installed. With two SCBs installed,
the DPC can be installed in any of two consecutive interface card slots, the range is
from 1 through 2.
For DPCs, the PIC and port numbers are identified on the DPC front panel. Use the
PIC and port numbers that correspond to the port you are configuring.
link-mode (full-duplex | half-duplex);
}
}
[edit interfaces]
ge-2/0/0 {
switch-options {
switch-port 0 {
no-auto-negotiation;
speed 1g;
link-mode full-duplex;
}
switch-port 1 {
no-auto-negotiation;
speed 10m;
link-mode half-duplex;
}
}
}
identifies the number of the FPC or DPC card on which the physical interface is
Chapter 33: Configuring Ethernet Interfaces
ge-fpc/pic/port
to identify interfaces.
MX Series Router Interface Identifiers