Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual page 944

Network interfaces configuration
Table of Contents

Advertisement

JUNOS 10.1 Network Interfaces Configuration Guide
You can configure the following ISDN options:
NOTE: TEI assignment is usually done dynamically instead of statically using the TEI
management protocol. When the TEI management protocol is used, values 64-126
are assigned to terminal endpoints. TEI value 127 is used for group assignment.
874
Configuring ISDN Physical Interface Properties
calling-number number;
incoming-called-number number <reject>;
spid1 spid-string;
spid2 spid-string;
static-tei-val value;
switch-type (att5e | etsi | ni1 | ntdms100 | ntt);
t310 seconds;
tei-option (first-call | power-up);
}
dialer-options {
pool pool-name <priority priority>;
}
—The calling number included in outgoing calls.
calling-number
incoming-called-number
—Screening of incoming calls. If the incoming number of
the incoming call is configured, the call is accepted. If the reject option is specified
with the number, the call is rejected. If no numbers are configured, all calls are
accepted. See "Configuring an ISDN Interface to Screen Incoming Calls" on
page 875.
—The dial pool for logical and physical ISDN interfaces. The dial pool allows
pool
logical (dialer) and physical (
dynamically on a per-call basis. On a dialer interface, pool directs the dialer
interface to a dial pool. On a
which the interface belongs. Specify a priority value from 0 (lowest) to 255
(highest) for the interface.
spid1
—The Service Profile Identifier (SPID).
service provider requires SPIDs, you cannot place calls until the interface sends
a valid, assigned SPID to the service provider when accessing the ISDN
connection. A single SPID must be configured as
spid2
—A second SPID, used for DMS-100 and NI1switch types.
—A static Terminal Endpoint Identifier (TEI) value. The TEI value
static-tei-val
represents any ISDN-capable device attached to an ISDN network that is the
terminal endpoint. TEIs are used to distinguish between different devices using
the same ISDN links. Specify a value from 0 through 63. You cannot configure
a TEI value with multiple SPIDs—dynamic TEI assignment is required.
—The ISDN switch type. The following switches are compatible:
switch-type
att5e
—AT&T 5ESS
—NET3 for United Kingdom and Europe
etsi
ni1
—National ISDN-1
br-pim/0/port
) interfaces to be bound together
interface, pool defines the pool to
br-pim/0/port
spid-string
is a numeric value. If your
spid1
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos 10.1