Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual page 1223

Network interfaces configuration
Table of Contents

Advertisement

hold-interval (OAM)
Syntax
hold-interval minutes;
Hierarchy Level
[edit protocols oam ethernet connectivity-fault-management maintenance-domain
Statement introduced in JUNOS Release 8.4.
Release Information
The time to wait before flushing the maintenance end point (MEP) database, if no
Description
updates occur.
Options
minutes
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
hold-interval (Protection Group)
hold-interval number;
Syntax
[edit protocols protection-group ethernet-ring name]
Hierarchy Level
Statement introduced in JUNOS Release 9.4.
Release Information
Specify the hold-off timer interval for all rings in 100 millisecond (ms) increments.
Description
Options
number
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
domain-name maintenance-association ma-name continuity-check]
—Time to wait, in minutes.
Configuring the Continuity Check Hold Interval
—Hold-timer interval, in milliseconds.
Range: 0 through 10,000 ms
Default: 100 ms
Ethernet Ring Protection Switching Overview on page 851
Chapter 62: Summary of Interface Configuration Statements
hold-interval (OAM)