JUNOS 10.1 Network Interfaces Configuration Guide
crc-major-alarm-threshold
crc-major-alarm-threshold (1e-3 | 5e-4 | 1e-4 | 5e-5 | 1e-5);
Syntax
[edit interfaces interface-name t1-options]
Hierarchy Level
Statement introduced in JUNOS Release 8.5.
Release Information
Major alarm error thresholds for T1 CRC errors. When the threshold is exceeded for
Description
one second, a defect condition is declared. If the defect condition continues for the
monitoring period, an alarm condition is declared.
10-second monitoring period for all settings except
Default
50-second monitoring period.
rate
Options
interface—To view this statement in the configuration.
Required Privilege Level
interface-control—To add this statement to the configuration.
Related Topics
1042
crc-major-alarm-threshold
—Error rate expressed as the number of errors per number of bits. The value
-3
is one error in 10
bits and
1e-3
Default:
5e-5
Configuring T1 CRC Error Major Alarm Thresholds on page 580
. The
1e-5
1e-5
-4
is five errors in 10
5e-4
value uses a
bits.