Example: Configuring Channelized Au-4 Interfaces; Configuring T3 Or Channelized T3 Interfaces Under Channelized Au-4 Interfaces; Example: Configuring T3 Or Channelized T3 Interfaces - Juniper JUNOS 10.1 - CONFIGURATION GUIDE 1-2010 Configuration Manual

Network interfaces configuration
Table of Contents

Advertisement

The OC-slice range is the range of SONET/SDH slices. For SDH interfaces, the OC-slice
range specifies the bandwidth size required for the interface type you are configuring.
Channelized AU-4 IQ interfaces must occupy three consecutive OC slices per interface,
in one of the following forms:
The interface type is the channelized interface type or data channel you are creating.

Example: Configuring Channelized AU-4 Interfaces

Configure channelized AU-4 interfaces, using partitions 1 through 4:
This configuration creates the interfaces

Configuring T3 or Channelized T3 Interfaces Under Channelized AU-4 Interfaces

To configure T3 or channelized T3 interfaces, include the
statements at the
or
This configuration creates the interfaces
ct3-fpc/pic/port:channel
NOTE: Class-of-service (CoS) rules cannot be applied to an individual channel
configured on channelized IQ interfaces. You can only apply CoS rules to the aggregate
bit streams.

Example: Configuring T3 or Channelized T3 Interfaces

Configure T3 and channelized T3 interfaces, using partition 1 and partition 2:
1–3
4–6
7–9
10–12
[edit interfaces cstm4-0/2/0]
partition 1 oc-slice 1-3 interface-type cau4;
partition 2 oc-slice 4-6 interface-type cau4;
partition 3 oc-slice 7-9 interface-type cau4;
partition 4 oc-slice 10-12 interface-type cau4;
[edit interfaces cau4-fpc/pic/port]
interface type:
ct3
[edit interfaces]
cau4-fpc/pic/port {
partition partition-number interface-type t3;
}
cau4-fpc/pic/port {
partition partition-number interface-type ct3;
}
.
Configuring Channelized OC12/STM4 IQ Interfaces (SDH Mode)
Chapter 19: Configuring Channelized OC12/STM4 Interfaces
cau4-0/2/0:1
through
partition
hierarchy level, specifying the
t3-fpc/pic/port:channel
cau4-0/2/0:4
.
and
interface-type
t3
and
451

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junos 10.1

Table of Contents