Almhist_Clr (Clear Alarm History) - YASKAWA SVC User Manual

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

4.2 Motion Command Details

4.2.20 ALMHIST_CLR (Clear Alarm History)

4.2.20 ALMHIST_CLR (Clear Alarm History)
When the ALMHIST_CLR command is executed, the alarm history data that is stored in the
SERVOPACK is cleared.
Execution and Operating Procedures
1.
Make sure that the following condition is met.
2.
Set the OW08 setting parameter (Motion Commands) to 21 to execute the ALM-
HIST_CLR motion command.
The alarm history data that is stored in the SERVOPACK is cleared.
The IW08 monitor parameter (Motion Command Response Code) is 21 during execution of this
command.
During command processing, bit 0 (Command Execution Flag) in the IW09 monitor parameter
will change to 1 (Processing). When processing is completed, this bit will change to 0 (Completed).
3.
Set OW08 to 0 to execute the NOP motion command.
This concludes the clear alarm history operation.
Holding and Canceling Commands
Bit 0 (Hold Command) and bit 1 (Cancel Command) in the OW09 setting parameter can-
not be used to stop the axis.
Related Parameters
The parameters that are related to this command are listed in the following table.
 Setting Parameters
Register
Address

OW

OW
Bit 0

OW
Bit 1
 Monitor Parameters
Register
Address

IL

IL

IW

IW
Bit 0

IW
Bit 1
4-84
No.
Execution Condition
Motion command execution for the target axis
1
must be completed.*
*
Before you change to this command during the execution of another command, you must check whether
the command can be changed and how operation changes when the command is changed. Refer to the
following section for details on changing from another command.
4.4 Changing the Command on page 4-137
Name
08
Motion Commands
09
Hold Command
09
Cancel Command
Name
02
Warnings
04
Alarms
Motion Command
08
Response Code
09
Command Execu-
tion Flag
09
Command Hold
Completed
Set this parameter to 21 (ALMHIST_CLR) to clear the alarm history.
This bit is ignored for the ALMHIST_CLR command.
This bit is ignored for the ALMHIST_CLR command.
Monitored Contents
This parameter reports the current warning status.
This parameter reports the current alarm status.
This parameter shows the motion command currently in execution.
This parameter is 21 during execution of the ALMHIST_CLR command.
This bit changes to 1 (Processing) during execution of the ALMHIST_-
CLR command. The bit changes to 0 (Completed) when execution ends.
This bit is always 0 (Command hold not completed) for the ALMHIST_-
CLR command.
Confirmation Method
IW08 must be 0 and bit 0 in
IW09 must be 0.
Setting Details
Continued on next page.