YASKAWA SVC User Manual page 549

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

Register No.

OW
78
Transmission Reference Output Data 24

OW
79
Transmission Reference Output Data 25

OW
7A
Transmission Reference Output Data 26

OW
7B
Transmission Reference Output Data 27

OW
7C
Transmission Reference Output Data 28

OW
7D
Transmission Reference Output Data 29

OW
7E
Transmission Reference Output Data 30

OW
7F
Transmission Reference Output Data 31
*
Communications are continued when the fixed parameters in the SVC Function Module are set as follows:
• When Communication Abnormality Detection Mask is enabled in Function Selection Flag 2
• When Communication Abnormality Detection Mask is disabled in Function Selection Flag 2 and Warning is
selected for Communication Selection Is Abnormal in Function Selection Flag 3
Name
Setting range: 0 to FFFFH
This data is sent as the 9th word in the subcom-
mand (subcommand bytes 16 and 17) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 10th word in the subcom-
mand (subcommand bytes 18 and 19) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 11th word in the subcom-
mand (subcommand bytes 20 and 21) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 12th word in the subcom-
mand (subcommand bytes 22 and 23) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 13th word in the subcom-
mand (subcommand bytes 24 and 25) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 14th word in the subcom-
mand (subcommand bytes 26 and 27) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 15th word in the subcom-
mand (subcommand bytes 28 and 29) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 16th word in the subcom-
mand (subcommand bytes 30 and 31) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Continued from previous page.
Description
10
10-47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svc32SvrSvr32