Register No.
OW
78
Transmission Reference Output Data 24
OW
79
Transmission Reference Output Data 25
OW
7A
Transmission Reference Output Data 26
OW
7B
Transmission Reference Output Data 27
OW
7C
Transmission Reference Output Data 28
OW
7D
Transmission Reference Output Data 29
OW
7E
Transmission Reference Output Data 30
OW
7F
Transmission Reference Output Data 31
*
Communications are continued when the fixed parameters in the SVC Function Module are set as follows:
• When Communication Abnormality Detection Mask is enabled in Function Selection Flag 2
• When Communication Abnormality Detection Mask is disabled in Function Selection Flag 2 and Warning is
selected for Communication Selection Is Abnormal in Function Selection Flag 3
Name
Setting range: 0 to FFFFH
This data is sent as the 9th word in the subcom-
mand (subcommand bytes 16 and 17) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 10th word in the subcom-
mand (subcommand bytes 18 and 19) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 11th word in the subcom-
mand (subcommand bytes 20 and 21) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 12th word in the subcom-
mand (subcommand bytes 22 and 23) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 13th word in the subcom-
mand (subcommand bytes 24 and 25) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 14th word in the subcom-
mand (subcommand bytes 26 and 27) when the
Transmission Reference subcommand is executed.
Note: Enabled only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 15th word in the subcom-
mand (subcommand bytes 28 and 29) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
Setting range: 0 to FFFFH
This data is sent as the 16th word in the subcom-
mand (subcommand bytes 30 and 31) when the
Transmission Reference subcommand is executed.
Note: Valid only in 64-byte Mode.
10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Continued from previous page.