10.4 Main Commands and Subcommands
10.4.3 Main Command Details
Monitor Parameters
Warning
Alarm
Command Response Code
Command Status
M-III Inverter Command Sta-
tus
M-III Command Status
Inverter Alarm Code
Inverter User Constant
Number
User Constant
Reading Data 1
User Constant
Reading Data 2
User Constant
Reading Data 3
User Constant
Reading Data 4
Write User Constant
Description
Writes the specified inverter user constant to a constant in the Inverter.
Note: You must execute the User Constant RAM Writing command to enable the data written by executing the
Setting Parameters
Command
Inverter User Constant Number
Inverter User Constant Number
Size
Inverter User Constant Set Point 1
Inverter User Constant Set Point 2
Inverter User Constant Set Point 3
Inverter User Constant Set Point 4
10-24
Name
Register No.
IL02
IL04
IW08
IW09
IL2A
IW2C
IW32
IW3C
IW3E
IW3F
IW40
IW41
Write User Constant command. Refer to the following section for details.
User Constant RAM Writing on page 10-26
Name
Setting
Range
−
Bit
−
Bit
0 to 8
02: Read User Constant
Bit 0 (Command execution
flag)
Bit 3 (Command error com-
pleted status)
Bit
Bit 8 (Command execution
completed)
Bit
Inverter operating status
Bit
Inverter command processing status
0 to FFFFH
Inverter alarm code
−
0 to FFFFH
−
0 to 65535
−
0 to 65535
−
0 to 65535
−
0 to 65535
Register No.
Setting Range
OW08
0 to 8
OW3C
0 to FFFFH
OW3D
1 to 4
OW3E
0 to 65535
OW3F
0 to 65535
OW40
0 to 65535
OW41
0 to 65535
Remarks
ON during execu-
tion
ON when an error
occurs during
command pro-
cessing
OFF during execu-
tion, and ON when
execution is com-
pleted.
Remarks
03: Write User Constant
−
−
−
−
−
−