10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Register No.

OW

OW

OW

OW

OW

OW

OW

OW

OW

OW
10-44
Name
3D
Inverter User Constant Number Size
Inverter User Constant
3E
Set Point 1
Inverter User Constant
3F
Set Point 2
Inverter User Constant
40
Set Point 3
Inverter User Constant
41
Set Point 4
42
Auxiliary Inverter User Constant Number
43
Auxiliary Inverter User Constant Size
Auxiliary Inverter User Constant
44
Set Point 1
Auxiliary Inverter User Constant
45
Set Point 2
Auxiliary Inverter User Constant
46
Set Point 3
Continued from previous page.
Description
Setting range: 1 to 4 (words)
Set the size of the user constant to read by execut-
ing the Read User Constant command, or set the
size of the user constant to write by executing the
Write User Constant command, in words.
Each inverter user constant is composed of one
word. Therefore, setting the Inverter User Constant
Number Size enables the reading or writing of data
of 1 to 4 consecutive words at once.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
command.
Enabled when Inverter User Constant Number Size
= 1 to 4
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
command.
Enabled when Inverter User Constant Number Size
= 2 to 4.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
command.
Enabled when Inverter User Constant Number Size
= 3 or 4.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
command.
Enabled when Inverter User Constant Number Size
= 4.
Setting range: 0 to FFFFH
Set the leading number of user constants to read
by executing the Read User Constant subcom-
mand, or the leading number of user constants to
write by executing the Write User Constant sub-
command.
Note: Set the register number used for MEMO-
BUS communications.
Setting range: 1 to 4 (words)
Set the size of the user constant to read by execut-
ing the Read User Constant subcommand, or set
the size of the user constant to write by executing
the Write User Constant subcommand, in words.
Each inverter constant is composed of one word.
Therefore, setting the Inverter User Constant Num-
ber Size enables the reading or writing of data of 1
to 4 consecutive words at once.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
subcommand.
Enabled when Auxiliary Inverter User Constant
Number Size = 1 to 4.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
subcommand.
Enabled when Auxiliary Inverter User Constant
Number Size = 2 to 4.
Setting range: 0 to 65,535 (FFFFH)
Set the data to write for the Write User Constant
subcommand.
Enabled when Auxiliary Inverter User Constant
Number Size = 3 or 4.
Continued on next page.