11.3
MECHATROLINK-III I/O Module Settings
This section describes the settings for MECHATROLINK-III I/O Modules.
You must use IOWin to set the parameters of the I/O Modules with MECHATROLINK-III Commu-
nications (JEPMC-MTA2900-E, JEPMC-MTA2910-E, JEPMC-MTP2900-E, and
JEPMC-MTP2910-E).
Refer to the following manual for details.
Important
11.3.1
Link Assignment Tab Page Settings
When connecting a MECHATROLINK-III I/O Module, set up the slave device on the Link
Assignment Tab Page as given in the following table and save those settings.
VENDOR
Yaskawa Electric
co.
MECHATROLINK-III Compatible I/O Module User's Manual (Manual No.: SIEP C880781 04)
DEVICE
JAPMC-MC2320-E
SVC32
JEPMC-MTD2310-E
JEPMC-MTA2900-E
JEPMC-MTA2910-E
JEPMC-MTP2900-E
JEPMC-MTP2910-E
11.3 MECHATROLINK-III I/O Module Settings
11.3.1 Link Assignment Tab Page Settings
PROFILE
BYTE
16, 32, 48,
8, 16, 24, 32 8, 16, 24, 32
64
16, 32, 48,
8, 16, 24, 32 8, 16, 24, 32
64
Standard
16
I/O
32
16
64
64
: Can be set.
SIZE
SCAN
INPUT
OUTPUT
8
8
16
16
8
8
32
32
32
32
11
11-13