Phase (Issue Phase Reference) - YASKAWA SVC User Manual

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

4.2.24

PHASE (Issue Phase Reference)

The PHASE command is used for the synchronized operation of multiple axes in Phase Control
Mode, using the specified speed, phase bias, and speed compensation.
1. Torque feedforward compensation can be used with the PHASE command. The torque feed-
forward compensation is set in the OL0C setting parameter (Torque/Force Reference
Setting or Torque Feedforward Compensation). If torque feedforward compensation is not
Important
necessary, set OL0C to 0.
2. The torque can be limited with the OL14 setting parameter (Torque/Force Limit).
OL14 can be changed at any time. The intended operation may not be achieved if the
set value is too small.
Execution and Operating Procedures
1.
Make sure that all of the following conditions are met.
No.
1
2
3
*
Before you change to this command during the execution of another command, you must check whether
the command can be changed and how operation changes when the command is changed. Refer to the
following section for details on changing from another command.
4.4 Changing the Command on page 4-137
2.
Set the following setting parameters.
• OW01, Bit 3 (Speed Loop P/PI Switch)
• OW03, Bits 8 to B (Filter Type Selection)
• OL0C (Torque/Force Reference Setting or Torque Feedforward Compensation)
• OL10 (Speed Reference Setting)
• OW12 (Speed Limit)
• OL14 (Torque/Force Limit)
• OL28 (Phase Compensation Setting)
• OW31 (Speed Compensation)
3.
Set the OW08 setting parameter (Motion Commands) to 25 to execute the PHASE
motion command.
Synchronized operation through phase control is started.
The IW08 monitor parameter (Motion Command Response Code) is 25 during execution of this
command.
4.
Set OW08 to any code other than 25.
Phase control is turned OFF.
This concludes the phase control operation.
Operating Patterns
The following figure shows the operating pattern when the PHASE command is executed.
Speed (%)
0
Execution Condition
There must be no alarms.
The Servomotor's power must be ON.
Motion command execution for the target axis
must be completed.*
Position
4.2 Motion Command Details
4.2.24 PHASE (Issue Phase Reference)
Confirmation Method
Both IL02 and IL04 must be 0.
Bit 1 in IW00 must be 1.
IW08 must be 0 and bit 0 in
IW09 must be 0.
Time (t)
4
4-99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svc32SvrSvr32

Table of Contents