10.4 Main Commands and Subcommands
10.4.3 Main Command Details
Setting Parameters
Mode Settings 1
Command
Output Data Option Selec-
tion
Input Data Option Selection OW0D
Input Command
Speed Reference
Torque Reference
Torque Compensation
(Option)
Analog Output Terminal 1
Output
Analog Output Terminal 2
Output
Terminal Output
PID Target
Pulse Train Output
V/f Gain
Command Selection
Monitor Parameters
Warning
Alarm
Command Response Code
Command Status
Input Data Option Selection
Monitor
Output Frequency
Output Current
Motor Speed (Option)
Torque Reference (Option)
Encoder Count PG1
10-22
Name
Register No.
OW01
OW08
OW0C
OW10
OW11
OW12
OW13
OW14
OW15
OW16
OW17
OW18
OW19
OW1B
Name
Register No.
IL02
IL04
IW08
IW09
IW0D
IW11
IW12
IW13
IW14
IW15
Setting
Range
−
Bit
0 to 8
01: Inverter Drive Control
−
Bit
−
Bit
−
Bit
−
−
−
−
Enabled when the Output Data Option Selection
−
(OW0C), bit 0 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 1 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 2 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 3 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 4 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 5 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 6 is ON.
Enabled when the Output Data Option Selection
−
(OW0C), bit 8 is ON.
Setting
Range
−
Bit
−
Bit
0 to 8
01: Inverter Drive Control
Bit 0 (Command execution
flag)
Bit 3 (Command error com-
pleted status)
Bit
Bit 8 (Command execution
completed)
−
Bit
−
−
−
−
Enabled when Input Data Option Selection
−
(OW0D), bit 0 is ON.
Enabled when Input Data Option Selection
−
(OW0D), bit 1 is ON.
Enabled when Input Data Option Selection
−
(OW0D), bit 2 is ON.
Remarks
Remarks
ON while the com-
mand is being exe-
cuted
ON when an error
occurs during
command pro-
cessing
OFF during com-
mand execution,
and ON when
command execu-
tion is completed.