10.4 Main Commands and Subcommands
10.4.3 Main Command Details
 Setting Parameters
Mode Settings 1
Command
Output Data Option Selec-
tion
Input Data Option Selection OW0D
Input Command
Speed Reference
Torque Reference
Torque Compensation
(Option)
Analog Output Terminal 1
Output
Analog Output Terminal 2
Output
Terminal Output
PID Target
Pulse Train Output
V/f Gain
Command Selection
 Monitor Parameters
Warning
Alarm
Command Response Code
Command Status
Input Data Option Selection
Monitor
Output Frequency
Output Current
Motor Speed (Option)
Torque Reference (Option)
Encoder Count PG1
10-22
Name
Register No.
OW01
OW08
OW0C
OW10
OW11
OW12
OW13
OW14
OW15
OW16
OW17
OW18
OW19
OW1B
Name
Register No.
IL02
IL04
IW08
IW09
IW0D
IW11
IW12
IW13
IW14
IW15
Setting
Range
Bit
0 to 8
01: Inverter Drive Control
Bit
Bit
Bit
Enabled when the Output Data Option Selection
(OW0C), bit 0 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 1 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 2 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 3 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 4 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 5 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 6 is ON.
Enabled when the Output Data Option Selection
(OW0C), bit 8 is ON.
Setting
Range
Bit
Bit
0 to 8
01: Inverter Drive Control
Bit 0 (Command execution
flag)
Bit 3 (Command error com-
pleted status)
Bit
Bit 8 (Command execution
completed)
Bit
Enabled when Input Data Option Selection
(OW0D), bit 0 is ON.
Enabled when Input Data Option Selection
(OW0D), bit 1 is ON.
Enabled when Input Data Option Selection
(OW0D), bit 2 is ON.
Remarks
Remarks
ON while the com-
mand is being exe-
cuted
ON when an error
occurs during
command pro-
cessing
OFF during com-
mand execution,
and ON when
command execu-
tion is completed.
Continued on next page.