10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Register No.

OW

OW
10-38
Name
Bit 0: Torque Compensa-
tion (Option)
Bit 1: Analog Output Ter-
minal 1 Output
Bit 2: Analog Output Ter-
minal 2 Output
Bit 3: Terminal Output
Output Data
0C
Option
Selection
Bit 4: PID Target
Bit 5: Pulse Train Output
Bit 6: V/f Gain
Bit 7
Bit 8: Command Selec-
tion
Bits 9 to F
Bit 0: Motor Speed
(Option)
Bit 1: Torque Reference
Setting
Input Data
0D
Option
Selection
Bit 2: Encoder Count
PG1
Bit 3: Frequency
Reference (Option)
Continued from previous page.
Description
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Torque Compensation (OW13) will be
enabled when the Inverter Drive Control command
is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Analog Output Terminal 1 Output
(OW14) will be enabled when the Inverter
Drive Control command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Analog Output Terminal 2 Output
(OW15) will be enabled when the Inverter
Drive Control command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Terminal Output (OW16) will be
enabled when the Inverter Drive Control command
is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option PID Target (OW17) will be enabled
when the Inverter Drive Control command is exe-
cuted.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Pulse Train Output (OW18) will be
enabled when the Inverter Drive Control command
is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option V/f Gain (OW19) will be enabled when
the Inverter Drive Control command is executed.
Reserved
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the output data
option Command Selection (OW1B) will be
enabled when the Inverter Drive Control command
is executed.
Reserved
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
option Motor Speed (IW13) will be monitored
when the Inverter Drive Control command is exe-
cuted.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
option Torque Reference (IW14) will be moni-
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
option Encoder Count PG1 (IW15) will be
monitored when the Inverter Drive Control com-
mand is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
option Frequency Reference (IW16) will be
monitored when the Inverter Drive Control com-
mand is executed.
Continued on next page.