YASKAWA SVC User Manual page 86

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

 Negative Software Limit
Set the position to detect the software limit in the reverse direction for the MP3000.
No.
Name
14
Negative Software Limit
Setting Precautions
• If an axis attempts to move in the reverse direction past this position, a negative software limit
alarm occurs and bit 4 in the IL04 monitor parameter changes to 1.
• This parameter is valid when bit 2 (Enable Negative Software Limit) in fixed parameter No. 1 is
set to 1 (Enabled).
• The software limit is enabled only after bit 5 (Zero Point Return/Setting Completed) in the
IW0C monitor parameter changes to 1 (Completed). Refer to the following section for
details.
6.3 Software Limits on page 6-9
SERVOPACK Settings
 Motor Type Selection
Select the motor type to use.
No.
Name
29
Motor Type Selection
0: Rotary motor
1: Linear motor
 Encoder Selection
Set the encoder type to use.
No.
Name
30
Encoder Selection
0: Incremental encoder.
1: Absolute encoder.
2: Absolute encoder used as incremental encoder.
3: Reserved.
Setting Precautions
For linear motors, set the encoder type that matches the linear scale and SERVOPACK set-
tings.
SVC
Setting Range
−1
31
31
-2
to 2
SVC
Setting Range
0, 1
SVC
Setting Range
0 to 2
3.4 Motion Parameter Details
3.4.1 Fixed Parameter Details
Setting Unit
Default
31
Reference units
-2
Setting Unit
Default
0
Setting Unit
Default
0
3-33