10.4 Main Commands and Subcommands
10.4.3 Main Command Details
Alarm History Monitor
Description
Reads the Inverter alarm history.
Setting Parameters
Command
Inverter Alarm Monitor
Number
Monitor Parameters
Warning
Alarm
Command Response Code IW08
Command Status
M-III Inverter Command
Status
M-III Command Status
Inverter Alarm Code
User Constant RAM Writing
Description
Saves the parameter data written by executing Write User Constant in the Inverter volatile
memory to enable the data.
Setting Parameters
Command
10-26
Name
Register No.
OW08
OW32
Name
Register No.
IL02
IL04
IW09
IL2A
IW2C
IW32
Name
Register No.
OW08
Setting Range
0 to 8
05: Alarm History Monitor
0 to 3
Alarm monitor number
Setting
Range
−
Bit
−
Bit
0 to 8
05: Alarm History Monitor
Bit 0 (Command execution
flag)
Bit 3 (Command error com-
pleted status)
Bit
Bit 8 (Command execution
completed)
Bit
Inverter operating status
Bit
Inverter command processing status
0 to FFFFH
The alarm history that is read out.
Setting Range
0 to 8
06: User Constant RAM Writing
Remarks
Remarks
ON during execu-
tion
ON when an error
occurs during
command pro-
cessing
OFF during execu-
tion, and ON when
execution is com-
pleted.
Remarks