Register No.
Input Data
Option

OW
0D
Selection
(continued)
Name
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 4: Analog Input A2
option Analog Input A2 (IW17) will be moni-
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 5: Main Bus Voltage
option Main Bus Voltage (IW18) will be moni-
(Option)
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 6: Alarm Code
option Alarm Code (IW19) will be monitored
when the Inverter Drive Control command is exe-
cuted.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 7: Warning Code
option Warning Code (IW1A) will be moni-
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 8: Multi-Function
option Multi-Function Output Terminal (IW1B)
Output Terminal
will be monitored when the Inverter Drive Control
command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 9: Analog Input A3
option Analog Input A3 (IW1C) will be moni-
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit A: Multi-Function
option Multi-Function Input Terminal (IW1D)
Input Terminal
will be monitored when the Inverter Drive Control
command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit B: Analog Input A1
option Analog Input A1 (IW1E) will be moni-
tored when the Inverter Drive Control command is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit C: Encoder Count
option Encoder Count PG2 (IW1F) will be
PG2
monitored when the Inverter Drive Control com-
mand is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit D: Monitor data set in
option Monitor Data Set in F6-23 (IW20) will
F6-23
be monitored when the Inverter Drive Control com-
mand is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit E: Monitor data set in
option Monitor Data Set in F6-24 (IW21) will
F6-24
be monitored when the Inverter Drive Control com-
mand is executed.
Bit F
Reserved
10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Continued from previous page.
Description
Continued on next page.
10
10-39