Setting Parameters
Register Address
Zero Point Return
OW
3C
Method
Speed Reference Set-
OL
10
ting
OL
3E
Approach Speed
OL
40
Creep Speed
Zero Point Return
OL
42
Travel Distance
N-OT Only (OW3C = 17)
Operation after Origin Return Starts
1.
Travel is started at the approach speed until the N-OT signal is detected.
2.
When the N-OT signal is detected, the direction will be reversed and the axis will return
at the positioning speed.
3.
Positioning is performed when the status of the N-OT signal changes from ON to OFF
during the origin return operation.
4.
When the positioning operation has been completed, the machine coordinate system is
established with the position at the end of the positioning operation as the origin.
Speed Reference Setting
(OL
10)
Zero Point
Return Travel
Distance
(OL
42)
Origin
*2
N-OT
*1.
SERVOPACK P-OT signal.
*2.
SERVOPACK N-OT signal.
1. The travel distance after detecting a change in the status of the N-OT signal is the
Information
value of the Zero Point Return Travel Distance parameter. The positioning speed is the
value of the Speed Reference Setting parameter.
2. If a positive value is set for the approach speed, the command will end in an error.
3. If an overtravel signal is detected when the axis is moving at the positioning speed, an
overtravel alarm will occur.
4. Detecting changes in the overtravel signal status is performed with software process-
ing. Therefore, the position where positioning is completed depends on the high-
speed scan setting and positioning speed setting. Do not use this method if repeat
accuracy is required for the position where the origin return operation is completed.
5. The stop method when an overtravel signal is detected depends on the SERVOPACK
parameter settings.
Name
16: N-OT + C pulse
Set the positioning speed to use after the phase-C pulse is
detected. The sign is ignored.
The travel direction depends on the sign of the Zero Point
Return Travel Distance parameter.
Set the speed at which to begin the origin return operation.
Add a sign to this setting so that the travel direction will be neg-
ative.
Set the speed to use after the N-OT signal is detected.
The travel direction is positive.
Set the travel distance after the phase-C pulse is detected.
The travel direction depends on the sign.
Approach Speed
(OL
3E)
4.2 Motion Command Details
4.2.3 ZRET (Zero Point Return)
Setting Details
Start
*1
P-OT
4
4-37