YASKAWA SVC User Manual page 226

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

 Monitor Parameters
Register
Name
Address

IL
02
Warnings

IL
04
Alarms
Motion Command

IW
08
Response Code

IW
09
Command Execu-
Bit 0
tion Flag

IW
09
Command Hold
Bit 1
Completed

IW
09
Command Error End
Bit 3

IW
09
Command Execu-
Bit 8
tion Completed
SERVOPACK Alarm

IW
2D
Code
Timing Charts
 Normal Completion
OW
08 = 20 (ALM_HIST)
IW
08 = 20 (ALM_HIST)
IW
09 Bit 0 (BUSY)
IW
09 Bit 3 (FAIL)
IW
09 Bit 8 (COMPLETE)
IL
38
 Error Completion
OW
08 = 20 (ALM_HIST)
IW
08 = 20 (ALM_HIST)
IW
09 Bit 0 (BUSY)
IW
09 Bit 3 (FAIL)
IW
09 Bit 8 (COMPLETE)
IL
38
Monitored Contents
This parameter reports the current warning status.
This parameter reports the current alarm status.
This parameter shows the motion command currently in execution.
This parameter is 20 during execution of the ALM_HIST command.
This bit changes to 1 (Processing) during execution of the ALM_HIST
command. The bit changes to 0 (Completed) when execution ends.
This bit is always 0 (Command hold not completed) for the ALM_HIST
command.
This bit changes to 1 (Completed with an error) when an error occurs
during execution of the ALM_HIST command.
The axis will decelerate to a stop if it is moving. This bit changes to 0
(Completed normally) when another command is executed.
This bit changes to 1 (Normal execution completed) when operation of
the ALM_HIST command ends.
This parameter stores the SERVOPACK alarm code that was read.
This interval is
not constant.
Read results
Undefined value
This interval is
not constant.
Undefined value
4.2 Motion Command Details
4.2.19 ALM_HIST (Monitor Alarm History)
4
4-83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svc32SvrSvr32

Table of Contents