10.2 Setup Procedure

10.2.2 Inverter Settings

10.2.2 Inverter Settings

Use the following flowchart to make the Inverter settings.
STEP 1: Define the Module Configuration of the Inverter
STEP 2: Set the Required Fixed Parameters
STEP 3: Confirm That the Inverter Is Ready for Operation
STEP 4: Execute the Inverter Operation Control Command
STEP 5: Set the Required Setting Parameters
The procedures for STEP 1 to STEP 5 are given below.
STEP 1: Define the Module Configuration of the Inverter
You can define the Module configuration of the Inverter either automatically or manually.
 Automatic Definition Method
1.
Execute self configuration on the MP3000.
When you execute self configuration, information on the Modules that are connected to the MP3000
is detected and the Inverter I/O registers are assigned in the SVC definition file. Refer to the following
manual for the procedure to execute self configuration.
2.
Open the Module Configuration Tab Page. Refer to step 2 in
Method for the procedure.
3.
Confirm that communications have been established. Refer to steps 8 to 12 in the
Manual Definition Method for the procedure.
This concludes the procedure.
 Manual Definition Method
1.
Start the MPE720 on a computer that is connected to the MP3000.
2.
In the Main Window of the MPE720, click Setup - Module configuration from the
Launcher, or the Module Configuration Icon on the My Tool View of the Start Tab Page.
The Module Configuration Definition Tab Page will be displayed.
10-4
MP3000 Series Machine Controller Setup Manual (Manual No.: SIEP C880725 00)
Manual Definition