Bit 3: Alarm Clear Execution Completed (ALM_CLR_CMP)
0: Alarms cleared.
1: Alarms not cleared.
Bits 6 and 7: Echo-back of Command ID (RCMD_ID)
This parameter reports the echo-back value of the command ID of a MECHATROLINK com-
mand.
SERVOPACK Alarm Code
This parameter reports the alarm code from the SERVOPACK in BCD.
Refer to the relevant SERVOPACK manual for details on alarm.
Register
Address
IW2D SERVOPACK Alarm Code
SERVOPACK User Monitor Information
SERVOPACK User Monitor Information
This parameter reports the monitor selection that was made by the user when using a SERVO-
PACK with MECHATROLINK Communications.
Register
Address
IW2F
SERVOPACK User Monitor Information
• Bits 0 to 3: Monitor 1 (Cannot be set.)
• Bits 4 to 7: Monitor 2
• Bits 8 to B: Monitor 3 (Cannot be set.)
• Bits C to F: Monitor 4
SERVOPACK Information
SERVOPACK User Monitor 2
This parameter reports the monitor results selected in bits 4 to 7 (Monitor 2) in the OW4E
setting parameter.
Register
Address
IL30
SERVOPACK User Monitor 2
SERVOPACK User Monitor 4
This parameter reports the monitor results selected in bits C to F (Monitor 4) in the OW4E
setting parameter.
Register
Address
IW34
SERVOPACK User Monitor 4
SERVOPACK Parameter Number
This parameter reports the number of the SERVOPACK parameter that is being read or written
using the MECHATROLINK command area.
Refer to the following chapter for details.
Chapter 4 Motion Control Program Commands and Instructions
Register
Address
IW36
SERVOPACK Parameter Number
SVC
Name
SVC
Name
SVC
Name
SVC
Name
SVC
Name
3.4 Motion Parameter Details
3.4.3 Monitor Parameter Details
Range
−
-32,768 to 32,767
Range
−
−
Range
−
−1
31
31
-2
to 2
Range
−
−1
31
31
-2
to 2
Range
−
0 to 65,535
Unit
Unit
Unit
Unit
Unit
3-81