YASKAWA SVC User Manual page 212

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

 Monitor Parameters
Register
Name
Address

IL
02
Warnings

IL
04
Alarms
Motion Command

IW
08
Response Code

IW
09
Command Execu-
Bit 0
tion Flag

IW
09
Command Hold
Bit 1
Completed

IW
09
Command Error End
Bit 3

IW
09
Command Execu-
Bit 8
tion Completed
Timing Charts
 Normal Completion
OW
08 = 13 (CHG_FILTER)
IW
08 = 13 (CHG_FILTER)
IW
09 Bit 0 (BUSY)
IW
09 Bit 3 (FAIL)
IW
09 Bit 8 (COMPLETE)
 Error Completion
OW
08 = 13 (CHG_FILTER)
IW
08 = 13 (CHG_FILTER)
IW
09 Bit 0 (BUSY)
IW
09 Bit 3 (FAIL)
IW
09 Bit 8 (COMPLETE)
Monitored Contents
This parameter reports the current warning status.
This parameter reports the current alarm status.
This parameter shows the motion command currently in execution.
This parameter is 13 during execution of the CHG_FILTER command.
This bit is 1 (Processing) during execution of the CHG_FILTER com-
mand. The bit changes to 0 (Completed) when execution ends.
This bit is always 0 (Command hold not completed) for the CHG_FIL-
TER command.
This bit changes to 1 (Completed with an error) when an error occurs
during execution of the CHG_FILTER command.
The axis will decelerate to a stop if it is moving. This bit changes to 0
(Completed normally) when another command is executed.
This bit changes to 1 (Normal execution completed) when execution of
the CHG_FILTER command ends.
1 scan
4.2 Motion Command Details
4.2.12 CHG_FILTER (Change Filter Type)
4
4-69