YASKAWA SVC User Manual page 518

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

10.3 Precautions for Inverter Operation
Inverter Emergency Stopping and Restarting Methods
This section provides the procedures to perform an emergency stop (turning OFF the main cir-
cuit and control circuit power supplies and stopping operation commands) during Inverter
operation and the procedures for restarting the Inverter.
 Maintaining Drive Permission
1. Turn OFF the main circuit power supply.
2. To stop the operation command, turn OFF the Forward RUN and Reverse RUN commands.
The motor will perform an emergency stop.
Use the following steps to restart operation.
3. Execute an alarm clear operation to clear the device alarm.
4. Turn ON the main circuit power supply.
5. Start the operation command again.
Command
(OW
Drive Permission
(OW
Alarm Clear
(OW
Forward RUN or
Reverse RUN
(OW
Main circuit
power supply
Device Warning
Occurrence
(IW
Device Alarm Occurrence
(IW
Inverter Ready
(IL
Command Error
Completed Status
(IW
10-16
08)
00 bit D)
00 bit F)
10 bit 0 or 1)
2C bit 1)
2C bit 0)
2A bit 6)
09 bit 3)
Inverter Drive Control (= 1)