Register No.
Auxiliary
Input Data

OW
0F
Option
Selection
Name
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 0: Motor Speed
option Motor Speed (IW13) will be monitored
(Option)
when the Inverter I/O Control subcommand is exe-
cuted.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 1: Torque Reference
option Torque Reference (IW14) will be moni-
Setting
tored when the Inverter I/O Control subcommand is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 2: Encoder Count
option Encoder Count PG1 (IW15) will be
PG1
monitored when the Inverter I/O Control subcom-
mand is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 3 Frequency Refer-
option Frequency Reference (IW16) will be
ence (Option)
monitored when the Inverter I/O Control subcom-
mand is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 4: Analog Input A2
option Analog Input A2 (IW17) will be moni-
tored when the Inverter I/O Control subcommand is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 5: Main Bus Voltage
option Main Bus Voltage (IW18) will be moni-
(Option)
tored when the Inverter I/O Control subcommand is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 6: Alarm Code
option Alarm Code (IW19) will be monitored
when the Inverter I/O Control subcommand is exe-
cuted.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 7: Warning Code
option Warning Code (IW1A) will be moni-
tored when the Inverter I/O Control subcommand is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 8: Multi-Function
option Multi-Function Output Terminal (IW1B)
Output Terminal
will be monitored when the Inverter I/O Control sub-
command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit 9: Analog Input A3
option Analog Input A3 (IW1C) will be moni-
tored when the Inverter I/O Control subcommand is
executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit A: Multi-Function
option Multi-Function Input Terminal (IW1D)
Input Terminal
will be monitored when the Inverter I/O Control sub-
command is executed.
0: Disabled, 1: Enabled
When this bit is set to 1 (enabled), the input data
Bit B: Analog Input A1
option Analog Input A1 (IW1E) will be moni-
tored when the Inverter I/O Control subcommand is
executed.
10.5 Motion Parameter Details
10.5.2 Setting Parameter List
Continued from previous page.
Description
Continued on next page.
10
10-41