4.2.22 VELO (Issue Speed Reference)
Operating Patterns
The following figure shows the operating pattern when the VELO command is executed.
VELO Operating Pattern
Speed (%)
Holding
• To hold an axis in place during motion and resume operation at a later time, set bit 0 (Hold
Command) in the OW09 setting parameter to 1 (Hold Command ON).
When bit 0 in OW09 is set to 1, the axis will decelerate to a stop.
The deceleration operation depends on the setting of bits 8 to F (Stop Mode Selection) in the
OW02 setting parameter.
When the axis completely decelerates to a stop, bit 1 (Command Hold Completed) in the
IW09 monitor parameter will change to 1 (Completed).
• To release the hold, set bit 0 (Hold Command) in OW09 to 0 (Hold Command OFF).
This clears the command hold status and the remaining portion of the positioning operation is
restarted.
Canceling
• To cancel Speed Control Mode, set bit 1 (Cancel Command) in the OW09 setting
parameter to 1 (Cancel Command ON).
When bit 1 in OW09 is set to 1, the axis will decelerate to a stop.
The deceleration operation depends on the setting of bits 8 to F (Stop Mode Selection) in the
OW02 setting parameter.
When the axis completely decelerates to a stop, the remaining motion will be canceled and
bit 1 (Positioning Completed) in the IW0C monitor parameter will change to 1 (Within
positioning completed range).
• Speed Control Mode resumes if bit 1 (Cancel Command) in the OW09 setting parame-
ter is set to 0 (Cancel Command OFF) during processing of the cancel operation.
• The same operation as the Cancel Command operation will be performed if the motion com-
mand code is changed during operation in Speed Control Mode.
Important
Related Parameters
The parameters that are related to this command are listed in the following table.
4-90
0
Due to the delay that occurs when sending or receiving commands and responses between the
CPU and the Motion Control Function Module, the cancel processing may have been completed

(IW
08 is 23 and bit 8 in IW
operation. Set OW08 to any command other than VELO (e.g., NOP), and then start the
operation again.
If an operation is to be frequently canceled and restarted within a short interval, remember to
consider this delay.
Time (t)

09 is 1), even though an attempt was made to restart the