YASKAWA SVC User Manual page 559

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

Register
No.

IW
45
Auxiliary User Constant Reading Data 2

IW
46
Auxiliary User Constant Reading Data 3

IW
47
Auxiliary User Constant Reading Data 4

IL
48
Fixed Parameter Monitor

IW
4A
to

IW
5F

IW
60
Transmission Reference Input Data 0

IW
61
Transmission Reference Input Data 1

IW
62
Transmission Reference Input Data 2

IW
63
Transmission Reference Input Data 3

IW
64
Transmission Reference Input Data 4

IW
65
Transmission Reference Input Data 5

IW
66
Transmission Reference Input Data 6

IW
67
Transmission Reference Input Data 7

IW
68
Transmission Reference Input Data 8

IW
69
Transmission Reference Input Data 9

IW
6A
Transmission Reference Input Data 10

IW
6B
Transmission Reference Input Data 11

IW
6C
Transmission Reference Input Data 12
Name
Range: 0 to FFFFH
Displays the value read out by executing the
Read User Constant subcommand. Enabled
when Auxiliary Inverter User Constant Number
Size (OW43) = 2 to 4.
Range: 0 to FFFFH
Displays the value read out by executing the
Read User Constant subcommand. Enabled
when Auxiliary Inverter User Constant Number
Size (OW43) = 3 or 4.
Range: 0 to FFFFH
Displays the value read out by executing the Read
User Constant subcommand. Enabled when Auxiliary
Inverter User Constant Number Size (OW43) =
4.
Displays the fixed parameter value read out by
executing the Read Fixed Parameters subcom-
mand.
Reserved
Displays the 1st word in the response data (main
command bytes 0 and 1) when the Transmission
Reference command is executed.
Displays the 2nd word in the response data (main
command bytes 2 and 3) when the Transmission
Reference command is executed.
Displays the 3rd word in the response data (main
command bytes 4 and 5) when the Transmission
Reference command is executed.
Displays the 4th word in the response data (main
command bytes 6 and 7) when the Transmission
Reference command is executed.
Displays the 5th word in the response data (main
command bytes 8 and 9) when the Transmission
Reference command is executed.
Displays the 6th word in the response data (main
command bytes 10 and 11) when the Transmis-
sion Reference command is executed.
Displays the 7th word in the response data (main
command bytes 12 and 13) when the Transmis-
sion Reference command is executed.
Displays the 8th word in the response data (main
command bytes 14 and 15) when the Transmis-
sion Reference command is executed.
Displays the 9th word in the response data (main
command bytes 16 and 17) when the Transmis-
sion Reference command is executed.
Displays the 10th word in the response data
(main command bytes 18 and 19) when the
Transmission Reference command is executed.
Displays the 11th word in the response data
(main command bytes 20 and 21) when the
Transmission Reference command is executed.
Displays the 12th word in the response data
(main command bytes 22 and 23) when the
Transmission Reference command is executed.
Displays the 13th word in the response data
(main command bytes 24 and 25) when the
Transmission Reference command is executed.
10.5 Motion Parameter Details
10.5.3 Monitor Parameter List
Continued from previous page.
Description
Continued on next page.
10
10-57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svc32SvrSvr32

Table of Contents