Mechatrolink Detail Definition Dialog Box Details - YASKAWA SVC User Manual

Mp3000 series machine controller, motion control
Table of Contents

Advertisement

7.2 MECHATROLINK Communications Settings

7.2.2 MECHATROLINK Detail Definition Dialog Box Details

7.2.2

MECHATROLINK Detail Definition Dialog Box Details

The MECHATROLINK Detail Definition Dialog Box has four tab pages: Transmission Parame-
ters, Link Assignment, I/O Map, and Status. Click the tab to view each tab page.
Transmission Parameters Tab Page
The items on the Transmission Parameters Tab Page are described in the following table.
No.
Refer to the following section for details on each item.
 Item Details
This section provides details on the items that are displayed on the Transmission Parameters
Tab Page.
Important
7-8
Item
Master/Slave
My station address
Communication Cycle
Enabled message com-
munication
Number of retry to slaves
Number of connection
Slave synchronous func-
tion
Message Box
Item Details on page 7-8
Always save all settings to the flash memory after you change them.
Description
Set whether to use the SVC Function Module as a
master or a slave station.
Sets the local station address.
Sets the transmission cycle.
Enables or disables message communications.
Sets the maximum number of retries to execute within
one transmission cycle.
Sets the number of connected slave stations.
Enables or disables slave CPU synchronization.
Displays precautions on the high-speed scan time set-
ting.
Default
Master
01 hex
μ
250
s
Enable
1
8
Disabled

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svc32SvrSvr32