6.7.2

Selecting physical units

6.7.2.1

Select the motor standard

Selection options and parameters involved
The converter represents the motor data corresponding to motor standard IEC or NEMA in
different system units: SI units or US units.
Setting the motor standard using p0100 is part of quick commissioning. However, you can
also change p0100 after the quick commissioning.
Table 6- 31
Parame-
ter
r0206
p0307
p0316
r0333
p0341
p0344
r1969
Factory setting
1)
Converter with control units CU240D-2
Operating Instructions, 07/2016, FW V4.7 SP6, A5E34262100B AD
Parameters involved when selecting the motor standard
Designation
Power Module rated power
Rated motor power
Motor torque constant
Rated motor torque
Motor moment of inertia
Motor weight
Speed_cont_opt moment of
inertia determined
6.7 Application-specific functions
Motor standard IEC/NEMA, p0100 =
0
1)
IEC motor
NEMA motor
50 Hz, SI units
60 Hz, US units
kW
HP
kW
HP
Nm/A
lbf ft/A
Nm
lbf ft
kgm
lb ft
2
kg
Lb
kgm
lb ft
2
Advanced commissioning
1
2
NEMA motor
60 Hz, SI units
kW
kW
Nm/A
Nm
kgm
2
2
kg
kgm
2
2
189