Parameters
7.2 Parameter list
NOTICE
Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note
The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
r9451[0...29]

Units changeover adapted parameters / Unit_chngov par

Access level: 4
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency:
See also: F07088
r9463

Actual macro / Actual macro

Access level: 3
Can be changed: -
Unit group: -
Min:
0
Description:
Displays the set valid macro.
Note
A value of 0 is displayed if a parameter set by a macro is changed.
p9484

BICO interconnections search signal source / BICO s_s srch

Access level: 3
Can be changed: T, U
Unit group: -
Min:
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the number
(r9485) and the first index (r9486).
Dependency:
See also: r9485, r9486
r9485

BICO interconnections signal source search count / BICO s_s srch qty

Access level: 3
Can be changed: -
Unit group: -
Min:
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
Dependency:
See also: p9484, r9486
890
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Calculated: -
Scaling: -
Unit selection: -
Max:
999999
Calculated: -
Scaling: -
Unit selection: -
Max:
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max:
-
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
-
Data type: Unsigned32
Dynamic index: -
Function diagram: -
Factory setting:
0
Data type: Unsigned16
Dynamic index: -
Function diagram: -
Factory setting:
-