Siemens SINAMICS G150 Manual page 1334

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

4 Faults and alarms
4.2 List of faults and alarms
SI: Safety Integrated
STO: Safe Torque Off / SH: Safe standstill
N01620 (F, A)
SI P1 (CU): Safe Torque Off active
Message value:
-
Message class:
Safety monitoring channel has identified an error (10)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The "Safe Torque Off" (STO) function of the basic functions has been selected on the Control Unit (CU) using the
input terminal and is active.
Note:
- This message does not result in a safety stop response.
- This message is not output when STO is selected using the Extended Functions.
Remedy:
Not necessary.
Note:
CU: Control Unit
SI: Safety Integrated
STO: Safe Torque Off / SH: Safe standstill
Reaction upon F:
OFF2
Acknowl. upon F:
IMMEDIATELY (POWER ON)
Reaction upon A:
NONE
Acknowl. upon A:
NONE
N01621 (F, A)
SI P1 (CU): Safe Stop 1 active
Message value:
-
Message class:
Safety monitoring channel has identified an error (10)
Drive object:
VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The "Safe Stop 1" (SS1) function has been selected on the Control Unit (CU) and is active.
Note:
This message does not result in a safety stop response.
Remedy:
Not necessary.
Note:
CU: Control Unit
SI: Safety Integrated
SS1: Safe Stop 1 (corresponds to Stop Category 1 acc. to EN60204)
Reaction upon F:
NONE (OFF3)
Acknowl. upon F:
IMMEDIATELY (POWER ON)
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F01625
SI P1 (CU): Sign-of-life error in safety data
Message value:
%1
Message class:
Internal (DRIVE-CLiQ) communication error (12)
Drive object:
VECTOR_G
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The drive-integrated "Safety Integrated" function on the Control Unit (CU) has detected an error in the sign-of-life of
the safety data between the two monitoring channels and has initiated a STOP A.
- there is either a DRIVE-CLiQ communication error or communication has failed.
- a time slice overflow of the safety software has occurred.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
1334
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents