How to use the Maintenance book
2. Enter y in the appropriate fields to restrict the following alarm reports
(shown in
!
3. After you have made your choices to tailor the report, press
The Alarm Report log appears.
Port
Maintenance On
Name
01C1008
DID-TRK
Screen 2. Alarm Report log screen
4. Note the value in the Port field.
In our example, a DID trunk port in slot 10, carrier C has a MAJOR alarm,
and the alarmed port address is 01C1008.
5. Type display errors and press
The Alarm Report query screen appears
see all alarms or if you want to restrict the list to certain kinds of errors.
The screen reflects the changes you made in Step 2.
Generally, unless you suspect a problem occurred within a certain time
frame or with a particular component of the system, press
accumulated system errors
Port
Mtce
Alt
Name
Name
01C1008
DID-TRK
Screen 3. Hardware Error Report - Active Alarms
6. Note the Error Type (Err Type field) value and the Aux Data value if
present.
In our example, the Error Type is 1547.
555-233-119
Screen 1
in bold):
Active
Major
Minor
Warning
CAUTION:
If you enter n for major alarms and y for minor and warning alarms,
you will not see the macro-level information that you may need to
determine what is wrong with the system.
ALARM REPORT
Alt
Alarm
Svc
Brd? Name
Type
State
y
MAJOR
HARDWARE ERROR REPORT - ACTIVE ALARMS
Err
Aux
First
Type
Data
Occur
1547
03/09/00:20 03/15/01:18 255 1
Ack?
Date
1 2
Alarmed
03/09/00:30 00/00/00:00
.
Enter
(Screen
1), asking if you want to
(Screen
3).
Last
Err Err Rt/ Al Ac
Occur
Cnt Rt
Issue 5 October 2002
.
Enter
Date
Resolved
to see the
Enter
Hr
St
7
a
y
33
Need help?
Do you have a question about the DEFINITY Server CSI and is the answer not in the manual?