Upgrading Communication Manager—R2.0 to R2.X

Clear alarms

1
Under Alarms and Notification, click View Current Alarms.
2
Select the server alarms to be cleared and click Clear.
3
Resolve any major alarms using SAT commands on a terminal emulation application.

Start a SAT session

1
Open a terminal emulation application, such as Avaya Terminal Emulator or MS HyperTerminal.
2
Type 192.11.13.6
3
Log on as craft or dadmin.

Check link status

1
Enter
display communication-interface links
2
Note all administered links.
3
Type status link
Check the following fields for the values listed:
4
Type
list signaling group
5
Note the signaling groups listed by number.
6
For each of the signaling groups listed, type
7
If any of the links are not up, make note of any that are down.

Record all busyouts

1
Type
display errors
busied out, so you can return them to their busy-out state after the upgrade.
24
NOTE:
Tasks

Start a SAT session

use SAT commands.
5023
and press Enter.
NOTE:
Because some links may be down by choice, make note of them before the upgrade.
number
and press Enter for each administered link.
Link Status = connected
Service State = in service
and press Enter.
and press Enter. Look for type 18 errors and record any trunks that are
Upgrading Software and Firmware—S8500 Configuration
on page 24 through
Check for translation corruption
and press Enter.
status signaling group number
on page 26
and press Enter.